7.11.9
RD378 Privacy Zones, Continued
When setting view 90 position, the zoom position is stored. If the operator then zooms
out from this position the privacy zone is disabled. However zooming into this position
or any closer enables the privacy zone and excludes the operator from panning or tilting
into the area. If the operator zooms out, then pans/tilts into the zone, and then tries to
zoom in, the zoom will be halted when the zoom position set at the view is reached.
Pan/tilt will still be enabled to allow the operator to exit the zone. If the privacy zone is
required for all zoom positions, then views 90 and 91 must be set fully zoomed out.
The same procedure is used to set the other 4 privacy zones. See diagram below.
View 90
View 92
View 94
View 96
View 98
The zoom position for each privacy zone is set when the bottom left corner of each zone
is set. This means each zone will have its own privacy zoom setting.
Privacy Zone Alarms
When the operator pans, tilts or zooms into a privacy zone, as well as that action being
halted, an alarm message is sent back to the MAXPRO-Net system. This can be used to
output a message to the screen identifying the privacy zone reached. Privacy zone 1
corresponds to alarm 1, zone 2 to alarm 2 etc. Note that this function means the alarm
inputs on the optional IO-378 board cannot be used, as the message sent to the
MAXPRO-Net on an alarm condition will be the same as if a privacy zone has been
reached.