7.11.9
RD378 Privacy Zones, Continued
This is done because a view recall is usually terminated when any pan/tilt control input is
received from the keyboard. Therefore an operator could perform a view recall, and then
cancel it whilst in the middle of a privacy zone. By disabling pan, tilt and zoom functions
while passing through the privacy zone, this problem is avoided. The privacy zone
alarm messages are sent as normal when the privacy zone is reached.
The RD-378 does not allow views to be set on the edge of an existing privacy zone.
Therefore move away from any privacy zones before setting views. There may
occasionally be a requirement for a view to be set up within privacy zones. In this case,
set the view first, and then set the privacy zone.
MAXPRO-Net Information
100 views (and therefore allow privacy zones to be set), a key intercept is required
from the <VIEW> key. (Refer to MAXPRO-Net commissioning manual regarding
intercepting keyboard keys). The key replacement macro required for 100 views is v
(lower case).
privilege to set views (Refer to MAXPRO-Net commissioning manual regarding
Keyboard Operators). Otherwise, operators would easily be able to re-position or
disable privacy zones.
7.11.10
IO-378 Optional I/O Expansion Board
The IO-378 plugs into the 20-way boxed header (J1) on the RD-378 via a ribbon cable.
The board is supported by stand-offs. The IO-378 provides relay output contacts, alarm
inputs and lens iris control.
Relay Outputs
Eight separate relay output contacts are provided. Six of these outputs are rated at 1A
@30V. Outputs 7 and 8 have a higher rating of 2A @30V and are intended for wash and
wipe motors respectively. When enabled in the MAXPRO-Net software, four of the
outputs are utilized for special functions. These are:
Rev. C
The default number of views accessible in MAXPRO-Net is 10. To enable the full
Obviously it is important to ensure only supervisors have the specific access
NOTE: On the RD-378 set switch SW3-6 ON. This
enables the RD-378 to control the IO-378.
NOTE: Always remove the right-angle connectors from
the RD-378 PCB prior to fitting the IO-378, otherwise the
board will not fit correctly.
Relay 5 Manual Iris open.
Relay 6 Manual Iris close
Relay 7 Wash control
Relay 8 Wipe Control