7.2.1
Switch Settings, Continued
SW1
ON
ON
(DEFAULT)
ON
ON
OFF
OFF
OFF
7.2.2

Jumper JP1

This jumper controls the IRQ number for port 1 interrupt. Setting the jumper in the top
position selects IRQ3 (default), and in the bottom position selects IRQ4. Selecting IRQ4
may be required in some high-level interface applications. Ports 2 to 8 (or ports 2 to 4
with the MX04) are fixed at interrupt IRQ3.
Rev. C
MX04 Switch Settings
SW2
SW3
PORT 1
ON
ON
$3F8~
$3FF
ON
OFF
$160~
$167
OFF
ON
$2A0~
$2A7
OFF
OFF
$2F8~
$2FF
ON
ON
$1A0~
$1A7
ON
OFF
$180~
$187
OFF
ON
$3F8~
$3FF
7.2-2
PORT 2
PORT 3
PORT 4
$2F8~
$2B0~
$2B8~
$2FF
$2B7
$2BF
$168~
$170~
$178~
$16F
$177
$17F
$2A8~
$2B0~
$2B8~
$2AF
$2B7
$2BF
$2A8~
$2B0~
$2B8~
$2AF
$2B7
$2BF
$1A8~
$1B0~
$1B8~
$1AF
$1B7
$1BF
$188~
$190~
$198~
$18F
$197
$19F
$2F8~
$3E8~
$2E8~
$2FF
$3EF
$2EF