Warnings - Cisco D9824 Installation And Configuration Manual

Advanced multi decryption receiver
Table of Contents

Advertisement

Chapter 6 Service and Maintenance
Alarm
Message
Type
FPGA status
Set
FPGA status
Set
FPGA status
Clear

Warnings

Warning
Message
Type
ASI TS
Set
Overflow
ASI TS
Clear
Overflow
252
Message
Cause/Remedy
FPGA ID does not
Cause: Hardware
match FPGA
issue.
DESIGNATION
Remedy: Clear
alarms, reset the
unit, notify
customer service if
the problem
persists.
FPGA ID does not
Cause: Hardware
match HW FPGA
issue.
ID
Remedy: Clear
alarms, reset the
unit, notify
customer service if
the problem
persists.
FPGA loaded
successfully and
reset
Message
Cause/Remedy
ASI Output
Cause: Uplink settings
Overflow
may have changed since
setting up the unit.
Remedy: Increase the
output rate, drop
unreferenced content in
DPM Options, and drop
the programs that are
not needed for
downstream devices.
Contact your (uplink)
service provider to
verify the expected bit
rate settings.
ASI Output
Overflow
Cleared
Description
Severity
FPGA setup
Major
failure or the
FPGA binary
identity does
not match the
FPGA registers.
FPGA setup
Major
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Description
The output rate is
higher than level set
by the user.
78-4039426-01 Rev D