Cisco D9824 Installation And Configuration Manual page 126

Advanced multi decryption receiver
Table of Contents

Advertisement

Chapter 4 Front Panel Operation
To synchronize the output to the input PIDs only:
This operation synchronizes the inputs to the outputs according to the PID
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1
On the DPM menu, map the output services as desired.
2
Select PE Resync: PIDs. The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment categories/names.
To synchronize the output to All (Services and PIDs):
This operation synchronizes the inputs to the outputs of the current PMT according
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1
On the Detailed Program Mapping Active menu, map the outputs services as
desired.
2
Select PE Resync: All. The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
To synchronize the output to a Template:
Using a template allows you to preset the input to output mapping of a PE according
to the preset template. This is helpful in pre-configuring any number of PEs for
future use.