Chapter 6 Service and Maintenance
Alarm
Message
Type
Signal Quality
Set
Signal Quality
Clear
Signal Quality
Clear
Transport
Set
Processing
Transport
Clear
Processing
Version
Set
Mismatch
DL:NVS Flash
Set
Failure
244
Message
Cause/Remedy
Poor Quality RF
Cause: RF Signal
Signal
quality is poor due
to interference or
signal level issues.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.
Signal Quality
Fault Cleared
Audio Unmuted
PTI lockup
Cause: Possible
software issue.
Remedy: Clear
alarms, reset unit,
and notify
customer service if
problem persists.
PTI running
Version Mismatch
Cause: App5514
between
version does not
5514/7109
match App7109
version.
Remedy:
Download code
with identical
App5514 and
App7109 versions.
APP5514 Flash
Cause: Possible
Write Failed
hardware or
software issue.
Remedy: Clear
alarms, reset unit,
and notify
customer service if
problem persists.
Description
Severity
Signal is locked
Minor
but BER is
beyond muting
threshold.
Minor
Minor
Programmable
Minor
transport input
module
stopped
processing any
data packet.
Minor
Version
Major
mismatch
between code
running 5514
and 7109
processors.
Failed to read
Major
or write flash
memory