Chapter 6 Service and Maintenance
Alarm
Message
Type
FPGA
Set
Temperature
Alarm
FPGA
Clear
Temperature
Alarm
ASI Out Status
Set
ASI Out Status
Clear
246
Message
Cause/Remedy
Temperature over
Cause: Room
Alarm threshold
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
Temperature
normal
ASI Overflow.
Cause: Uplink
Output Muted.
settings may have
Reduce content.
changed since
setup of the unit.
Variable Bit
Rate/Statmuxed
streams may be in
use.
Remedy: Increase
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.
ASI Output
Restored
Description
Severity
FPGA
Major
temperature is
above safe
operating
range.
Current
Minor
transport rate
exceeds
configured rate
for ASI output.
Output has
been muted to
protect
downstream
devices.
Minor
78-4039426-01 Rev D