Mitsubishi Electric MELSEC Q Series User Manual page 425

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Return value
*1
(HEX)
The number of device points is out of range.
16449
(4041
)
H
The specified device is not accessible.
16450
Corresponding module error.
(4042
)
H
The specified intelligent function module does not exist.
16451
In a single CPU system configuration, an access to the CPU shared memory of the C
(4043
)
H
Controller module was attempted.
Access to an inaccessible CPU shared memory area was attempted.
16480
Online registration error
(4060
)
• The online debug function is currently running on another peripheral device.
H
16523
Remote request not executable
(408B
)
H
16641
The number of write data is out of the storage device range for data to be written.
(4101
)
H
An inaccessible buffer memory address was specified.
16716
(414C
)
H
The inaccessible CPU shared memory address was specified.
The specified destination CPU module is wrong.
A CPU No. set as reserved was specified.
17232
A CPU No. not mounted was specified.
(4350
)
H
The start I/O No. of the destination CPU module divided by 10
3E0
to 3E3
.
H
H
The instruction cannot be executed on the specified target CPU module.
17233
• The instruction name is wrong.
(4351
)
H
• A non-supported instruction was executed on the target CPU module.
17234
The number of devices of the specified instructions is wrong.
(4352
)
H
17235
An inapplicable device was specified in the specified instruction.
(4353
)
H
17236
A non-supported string was specified in the specified instruction.
(4354
)
H
17237
The number of write data is out of the range of 1 to 20.
(4355
)
H
• Network No. or station No. is incorrect.
18944
• Routing parameter does not exist in other network settings
(4A00
)
• The module with relay network No. and station No. specified in the routing
H
parameter settings is not mounted.
19200
An error was detected in the target.
(4B00
)
H
19201
The target is not the bus master CPU (CPU 1).
(4B01
)
H
19203
Unsupported communication path error
(4B03
)
• The request cannot be executed via the specified communication path/target.
H
The instruction for the multiple CPU system is not supported by operating system of
19457
the Motion CPU. (The error code returned by the Motion CPU)
(4C01
)
H
 Refer to the manual of the Motion CPU currently used.
19458
Motion SFC program No. error (the error code returned by the Motion CPU)
(4C02
)
 Refer to the manual of the Motion CPU currently used.
H
Error description
is out of the range of
H
Corrective action
• Check the start address and number of access points.
• When specifying a size of 32768(8000
H
"functions for compatibility" with "available functions".
 Page 356, Section 21.2, Page 362, Section 22.2
Check the start address and the number of access points, and access an
accessible device.
Check if the specified module is operating normally.
Check the I/O number and network No. of the specified intelligent function
module.
To access the CPU shared memory of the C Controller module, configure a
multiple CPU system.
Check the specified CPU shared memory area.
• After the operation has ended on the other peripheral device, execute the
function once again.
• In a case where the operation is in progress or the operation has been
suspended on the other peripheral device, execute the operation once
again on the other peripheral device, wait for the operation to end
normally, and then execute the operation once again.
Allow "Remote reset" in Setting/monitoring tools for the C Controller module,
and then execute remote reset.
Check and revise the program to a proper user program.
Check and correct the buffer memory address.
Check and correct the CPU shared memory address.
Check and revise the program to a proper user program.
• Check the specified network No. and station No..
• Check the routing parameter settings.
• Check the target.
• Confirm the error occurred in the target or relay station, and then take a
corrective action.
If the target is not the bus master CPU (CPU 1), it cannot execute remote
reset.
• Check the communication path/target that supports the request.
• Do not issue a request that has generated an error to a C Controller
module.
• When sending a request to the own station, select station No. 255 (FF
Check the user program on C Controller module.
APPENDICES
) bytes or more, replace the
).
H
423
A

Advertisement

Table of Contents
loading