Mitsubishi Electric MELSEC Q Series User Manual page 159

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Item
Parameter error
Parameter setting check
Link parameter error
Intelli-parameter error
Refresh time over
Network No. duplication error
CPU error
System watchdog timer error
User watchdog timer error
Multiple CPU system error
Other CPU critical error
Multiple CPU execution error
Multiple CPU consistency
error
Other CPU minor error
*1 :
When "Stop" is detected in CPU operating status, no script file is executed.
*2 :
How many times a momentary stop was detected can be confirmed by the C Controller module dedicated function
(CCPU_GetPowerStatus).
While the C Controller module is detecting "Main CPU error", "Momentary stop detection" (including detection count update) and
"Power OFF detection" are not performed.
Further, the module may not be started up when this error occurs.
"Not checked" can be set in "Error check" in Project view  "Parameter"  "CCPU Parameter"  <<RAS settings >>in Setting/
*3 :
monitoring tools for the C Controller module.
*4 :
The CPU operation status for error detection can be changed to "Continue" in "Operation mode at the time of error" in Project view
 "Parameter"  "CCPU Parameter"  <<RAS settings >> in Setting/monitoring tools for the C Controller module.
*5 :
The CPU operation status for error detection can be changed to "Continue" in "H/W error time CPU operation mode" in Project
view  "Parameter"  "CCPU Parameter"  <<I/O assignment settings>> in Setting/monitoring tools for the C Controller
module.
*6 :
For error details, you may check information in special relays ( Page 478, Appendix 6), special registers ( Page 480,
Appendix 7).
*7 :
Whether to stop the multiple CPU system or not when an error occurs in CPU No.2, No.3, or No.4 can be set in "Operation mode"
in Project view  "Parameter"  "CCPU Parameter"  <<Multiple CPU settings>> in Setting/monitoring tools for the C Controller
module.
Error message
Diagnostic timing
PARAMETER ERROR
• At power-on, at reset
LINK PARA.ERROR
• At power-on, at reset
SP.PARA.ERROR
• At power-on, at reset
REF. TIME OVER
• At power-on, at reset
DUPLICAT.NET.NO.
• At power-on, at reset
SYSTEM WDT ERROR
• Any time
USER WDT ERROR
• Any time
• Any time
MULTI CPU DOWN
• At power-on, at reset
• Any time
MULTI EXE.ERROR
• At power-on, at reset
• Any time
CPU LAY ERROR
• At power-on, at reset
MULTI CPU ERROR
• Any time
CHAPTER 11 BASIC FUNCTIONS
CPU module
LED status
*1
RUN
status
-
Stop
Off
Stop
Off
Stop
Off
Continue
On
Stop
Off
-
Stop
Off
Stop
Off
-
*7
Off
Stop/Continue
*7
Off
Stop/Continue
*7
Off
Stop/Continue
Continue
On
ERR.
Flash
Flash
Flash
On
11
Flash
Flash
Flash
Flash
Flash
Flash
On
157