Mitsubishi Electric MELSEC Q Series User Manual page 299

Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

No.
Item
0E00
Number of CPU
H
0E01
Operation mode
H
E003
Normal area setting
H
I/O sharing when using
0E04
H
Multiple CPUs
E006
Online module change
H
Multiple CPU high speed
E008
H
transmission area setting
Multiple CPU
E00B
synchronous startup
H
setting
E00C
Host CPU number
H
Event history registration
FD00
H
settings
FD01
Account settings
H
IP address setting CH1
FD02
H
IP address setting CH2
FD03
Standard RAM settings
H
FD05
Restart user CPU
H
FD06
User WDT setting
H
FD07
Service setting
H
FD08
Password setting
H
FD09
IP address setting CH2
H
FD10
Refresh setting
H
FD11
Data refresh settings
H
FD12
Interrupt Settings
H
Meaning of "mn", "**", "M", and "N" in parameters is indicated below.
mn
: Start I/O No. divided by 10
**
: Any given value
N
: The module number
M
: Network type
Network types are indicated in the following table.
M
CC-Link IE Control (Control station), CC-Link IE Control Extended mode (Control station),
1
MNET/10 mode (Control station),
MNET/H mode (Control station), MNET/H Extended mode (Control station)
CC-Link IE Control (Normal station), CC-Link IE Control Extended mode (Normal station),
2
MNET/10 mode (Normal station),
MNET/H mode (Normal station), MNET/H Extended mode (Normal station)
8
CC-Link IE Field (Master station)
9
CC-Link IE Field (Local station)
M
0
Master station
1
Local station
Set in:
No.
FDD0
FDD1
<<Multiple CPU
Setting>>
FDD2
<<RAS Setting>>
<<Account settings>>
<<User Ethernet
FDD3
port (CH1 and CH2)
settings>>
<<System settings>>
<<RAS Setting>>
<<Security settings>>
<<Built-in Ethernet
FDD4
Port (CH1 and CH2)
Settings>>
<<System settings>>
<<Data refresh
settings>>
H
CC-Link IE / MELSECNET setting
Network type
CC-Link setting
Network type
Item
Q series bus interface
H
(Channel No.12)
CC-Link
(Channel No.81 to 88)
H
Channel No.
Target Settings
MELSECNET/H
(Channel No. 51 to 54)
Channel No.
H
Target Settings
Transient transmission size
CC-Link IE Controller
Network
(Channel No. 151 to 154)
H
Channel No.
Target Settings
Transient transmission size
CC-Link IE Filed Network
(Channel No. 181 to 188)
H
Channel No.
Target Settings
Transient transmission size
CHAPTER 15 PARAMETER
Set in:
<<MELSEC data link
function settings>>
<<MELSEC data link
function settings>>
CC-Link
<<MELSEC data link
function settings>>
MNET/H, MNET/10
<<MELSEC data link
function settings>>
CC IE Control
<<MELSEC data link
function settings>>
CC IE Field
297