Return value
*1
(HEX)
8194
The dedicated instruction which is not supported by the operating system of motion
(2002
)
CPU is executed.
H
8320
The number of write data points set by the D(P).DDWR instruction is invalid.
(2080
)
H
8321
The number of read data points set by the D(P).DDRD instruction is invalid.
(2081
)
H
8322
The interrupt pointer No. set by the D(P).GINT instruction is out of the range of 0 to 15.
(2082
)
H
• There were 33 or more instructions simultaneously requested from the
Programmable controller CPU/C Controller module to the Motion CPU in
D(P).GINT. The Motion CPU cannot process the instructions.
• There were 65 or more instructions simultaneously requested to the Motion CPU in
D(P).SFCS. The Motion CPU cannot process the instructions.
• There were 65 or more instructions (for Q172DS/Q173DS using SV13/SV22
8448
version B or later, 129 or more instructions) simultaneously requested from the
(2100
)
Programmable controller CPU/C Controller module to the Motion CPU in
H
D(P).SVST, D(P).CHGA, and D(P).CHGAS combined. The Motion CPU cannot
process the instructions.
• There were 65 or more instructions simultaneously requested from the
programmable controller CPU/C language controller module to the Motion CPU in
D(P).DDRD and D(P).DDWR combined. The Motion CPU cannot process the
instructions.
8704
The Motion SFC program number to be started is out of the range of 0 to 255.
(2200
)
4
8705
The servo program number to be executed is out of the range of 0 to 4095.
(2201
)
H
8706
The axis number set in the D(P).SVST instruction is invalid.
(2202
)
H
8707
The axis number set in the D(P).CHGA instruction is invalid.
(2203
)
H
8708
The axis number set in the D(P).CHGV instruction is invalid.
(2204
)
H
8709
The axis number set in the D(P).CHGT instruction is invalid.
(2205
)
H
8710
The axis number set in the D(P).CHGT2 instruction is invalid.
(2206
)
H
8711
The axis number set in the D(P).CHGAS instruction is invalid.
(2207
)
H
8712
The axis number set in the D(P).CHGVS instruction is invalid.
(2208
)
H
16384
(4000
)
H
to
Error detected in destination CPUs
20479
(4FFF
)
H
16385
(4001
)
H
An unprocessable request was received.
16386
(4002
)
H
16400
Not executable during running
(4010
)
H
16432
The specified device type does not exist.
(4030
)
H
• The specified device No. is out of range.
16433
• The block No., network No., start I/O No. / 10
(4031
)
is invalid.
H
• The specified device name is not supported by the CPU modules.
16448
The module does not exist.
(4040
)
H
422
Error description
, or CPU No. of the specified device
H
Corrective action
Check if the executed motion dedicated instruction is supported by the
operating system of motion CPU used.
Check the specified size.
Check the specified interrupt pointer No..
• Wait for the Motion CPU to process instruction requests, and try again.
• Reduce the number of instructions requested to the Motion CPU.
Check the specified SFC program No..
Check the specified servo program No..
Check the specified axis No..
Refer to the user's manual for the respective destination CPU module.
Change the request destination.
Reset the C Controller module when it is in the STOP status.
• Check the device type.
• Check if the device number is validated on the target station.
• Check the device No.
• When specifying device No.32768(8000
"functions for compatibility" with "available functions".
 Page 356, Section 21.2, Page 362, Section 22.2
• Check the block No., network No., start I/O No. / 10
(device type) of the specified device.
• On the target, check if the specified device, block No., network No., start
I/O No. / 10
, and CPU No. are valid.
H
• Check the device settings of the CPU modules.
• Check the device name.
Do not issue a request that generated an error to the specified special
function.
) or higher, replace the
H
, and CPU No.
H

Advertisement

Table of Contents