Technical data
ES1 and ES2 max output current
External supply of ES relay
Rated current per chain
Max. potential in relation to the cabinet earthing
and other signal groups.
Signal class
Connection to operating mode selector
The illustration below shows the connection of terminals for customer use.
xx0500002092
A
Technical data
Max. voltage
Max. current
Max. potential in relation to the cabinet earthing
and other signal groups.
Signal class
Product manual - IRC5
3HAC047136-001 Revision: M
Mode selector
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
2.5.12 The MOTORS ON/MOTORS OFF circuit
120 VAC: 4 A
48 VDC L/R: 50 mA
24 VDC L/R: 2 A
24 VDC R load: 8 A
24 VDC ± 10% between terminals X1:3,
7 and X2:7, 3 respectively.
Note
In case of interference, the external sup-
ply must be properly filtered.
40 mA
300 V
Control signals
48 VDC
4 A
300 V
Control signals
Continued