4 Repair
4.26.1 Replacement of power distribution unit
Continued
Required equipment
Equipment
Power distribution unit
Standard toolkit
Other tools and procedures
may be required. See refer-
ences to these procedures in
the step-by-step instructions
below.
Circuit diagram
Removal
The procedure below details how to remove the power distribution unit.
1
2
3
4
5
Continues on next page
288
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
Make sure that the main
power has been switched off on page
CAUTION
Hot surface on top of the power distribu-
tion unit.
Risk of burns. Be careful when removing
the unit.
Disconnect the connectors X1 - X9 on the
power distribution unit.
Loosen the left attachment screw, remove
the right attachment screw and pull the
power distribution unit rightward to re-
lease it from the left screw head.
Remove the power distribution unit.
© Copyright 2004-2018 ABB. All rights reserved.
Article number
3HAC026254-001
See
Circuit diagrams on
page
325.
Note/Illustration
26.
xx0700000122
A: left attachment screw
B: right attachment screw
Note
DSQC 662
The contents are defined in
section Standard toolkit.
Product manual - IRC5
3HAC047136-001 Revision: M