2.9.14 Installation of drive system fans with temperature sensors
Continued
4
5
Fitting the drive system fan with temp sensor
1
2
3
Continues on next page
180
Action
Strap the wires from the sensor together
with the other wires from the fan to avoid
the sensor wires to be damaged by sharp
edges.
Fit the sensor connector from below into
the inner hole on the bracket of the fan
holder.
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
Make sure that the main
power has been switched off on page
Insert the sensor between the heat sink
fins in the middle.
Route the fan cable behind the fan channel
bracket.
© Copyright 2004-2018 ABB. All rights reserved.
Note/illustration
xx1700001154
Note/illustration
26.
B
A
xx1500000858
A Sensor on sensor holder
B Sensor cable
C Fan channel bracket
Product manual - IRC5