Removal
The procedure below details how to remove the panel board unit.
1
2
3
4
Product manual - IRC5
3HAC047136-001 Revision: M
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
Make sure that the main power has been switched
off on page
26.
xx0200000023
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
The unit is sensitive to ESD on page 34
Disconnect all connectors.
Remove the lower attachment screw, and remove
the Panel Unit.
© Copyright 2004-2018 ABB. All rights reserved.
4 Repair
4.2 Replacement of panel board
Continued
Note/Illustration
Note
Make a note of any connections.
xx0400000812
A: fixed attachments
B: hole for attachment
screw
Continues on next page