ABB IRC5 Product Manual page 155

Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2
3
4
5
6
Product manual - IRC5
3HAC047136-001 Revision: M
2.9.9 Installing the Safety module DSQC1015 for SafeMove
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit please observe the safety in-
formation in section
The unit is sensitive
to ESD on page 34
Open the computer unit by removing the
attachment screws and lift off the cover.
Disconnect the fan connector.
CAUTION
Be careful with the fan cable when opening
and removing the upper cover. The fan
cable must not be stretched.
Remove the attachment screw on top of
the slot bracket.
Fit the Safety module in position by push-
ing it into the socket on the motherboard.
Refit the attachment screw on top of the
Safety module bracket.
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
Note/Illustration
xx1300000684
A Attachment screws (4 pcs.)
B Cover
xx1500001761
A Attachment screw
B Safety module
CAUTION
Always grip the board around the edges to
avoid damage to the board or its compon-
ents.
Continues on next page
Continued
A
B
A
B
155