2.9.14 Installation of drive system fans with temperature sensors
Action
Fit the sensor holder on the edge of the
fan channel bracket.
Fit the fan by placing the latches in the
back of the fan housing into the grooves
and press the fan down.
Slide the cable gland into the indentation
in the fan housing. Gently pull the cable
so there is no slack on the cable between
the sensor and the cable gland.
Connect the connectors to the fan.
Refit the cover and the attachment screws.
Refit the moist dust filter magazine. (Op-
tion)
© Copyright 2004-2018 ABB. All rights reserved.
2 Installation and commissioning
Note/illustration
B
A
xx1500000857
A Sensor holder
B Sensor cable
A
B
C
xx1500000856
A Fan
B Latches
C Grooves
D Temp sensor cable
E Cable gland
Continued
E
D
181