Advertisement

4 Repair
4.17 Replacement of Safety module DSQC1015 for SafeMove
Continued
2
3
4
5
Refitting the Safety module
1
Continues on next page
260
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit please observe the safety in-
formation in section
The unit is sensitive
to ESD on page 34
Open the computer unit by removing the
attachment screws and lift off the cover.
Disconnect the fan connector.
CAUTION
Be careful with the fan cable when opening
and removing the upper cover. The fan
cable must not be stretched.
Remove the attachment screw on top of
the slot bracket.
Remove the Safety module by pulling it out
of the socket on the motherboard.
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
Make sure that the main
power has been switched off on page
© Copyright 2004-2018 ABB. All rights reserved.
Note/Illustration
xx1300000684
A Attachment screws (4 pcs.)
B Cover
xx1500001761
A Attachment screw
B Safety module
CAUTION
Always grip the board around the edges to
avoid damage to the board or its compon-
ents.
Note/Illustration
26.
Product manual - IRC5
3HAC047136-001 Revision: M
A
B
A
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents