11.02
Reactions:
Remedy:
Program Continuation:
8034
Definitions:
Reactions:
Remedy:
Program Continuation:
8036
Definitions:
Reactions:
Remedy:
Program Continuation:
8038
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
8040
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
• Buy option
• Configure fewer link axes
Clear alarm with the RESET key. Restart part program
Option 'activation of axis containers' not set
The option for activating the axis container function in MD
$MN_AXCONF_LOGIC_MACHAX_TAB is not enabled.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
• Buy option
• Do not configure any containers
Clear alarm with the RESET key. Restart part program
Option: it is not allowed to set different IPO cycles or position control cycles with
NCU link.
The option for activating the FAST_IPO_LINK has not been set. For NCU link, all Ipo or
position control cycles must then be equal (see FAST-IPO-LINK description).
- Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
• Buy option
• Do not activate different Ipo or position control cycles (see
MN_IPO_SYSCLOCK_TIME_RATIO and
MN_POSCTRL_SYSCLOCK_TIME_RATIO).
Switch control OFF - ON.
Option 'activation of more than %1 lead link axes' not set
%1 = Number of axes
The option for the number of lead link axes does not match the number of configured axes
in the MD $MA_AXCONF_ASSIGN_MASTER_NCU.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
- Interpreter stop
• Buy option
• Configure fewer lead link axes
Clear alarm with the RESET key. Restart part program
Machine data %1 reset, corresponding option is not set
%1 = String: MD identifier
A machine data has been set that is locked by an option.
- Alarm display.
1 Alarms