Siemens SINUMERIK 840D Series Diagnostics Manual page 242

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
16924
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16925
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16926
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
16927
Parameters:
Definitions:
1-242
Abort by pressing Reset!
Clear alarm with the Delete key or NC START.
Channel %1 caution: program test modifies tool management data
%1 = Channel number
Tool management data is changed during program testing. It is not possible to automati-
cally rectify the data after termination of the program testing.
This error message prompts the user to make a backup copy of the data or to reimport the
data after the operation is terminated.
- Alarm display.
Please inform the authorized personnel/service department. Save tool data on MMC and
reimport data after "ProgtestOff".
Clear alarm with the Delete key or NC START.
Channel %1 program control: action %2 not allowed in the current state, action %3
active
%1 = Channel number
%2 = Action number/action name
%3 = Action number/action name
The action has been refused since a mode or sub-mode change (change to automatic
mode, MDA, JOG, overstoring, digitizing, etc.) is taking place.
Example: This alarm message is output if the Start key is pressed during a mode or sub-
mode change from, for example, automatic to MDA, before the NCK has confirmed selec-
tion of the mode.
- Alarm display.
Repeat action.
Clear alarm with the Delete key or NC START.
Channel %1 channel coordination: action %2 not allowed in block %3, marker %4 is
already set
%1 = Channel number
%2 = Action
%3 = Block number
%4 = Marker number
The action was denied, the marker was already set. Check the program.
Example:
SETM(1) ; CLEARM(1) ; Marker must be reset first.
SETM(1)
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Repeat action.
Clear alarm with the RESET key. Restart part program
Channel %1 action %2 at active interrupt treatment not allowed
%1 = Channel number
%2 = Action number/action name
This action may not be activated during interrupt processing (e.g. mode change).
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents