11.02
17040
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17050
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17055
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Channel %1 block %2 illegal axis index
%1 = Channel number
%2 = Block number, label
A read or write access has been programmed to an axial variable in which the axis name
cannot be unambiguously imaged on a machine axis.
Example:
Writing of an axial machine data
$MA_... [X]= ... ; but geometry axis X cannot be imaged on a machine axis because of a
transformation!
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Deselect transformation before writing the axial data (keyword: TRAFOOF) or use the
machine axis names as axis.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal value
%1 = Channel number
%2 = Block number, label
On accessing an individual frame element, a frame component other than TRANS, ROT,
SCALE or MIRROR was addressed or the function CSCALE has been given a negative
scale factor.
Example:
$P_UIFR[5] = CSCALE (X, -2.123)
The frame components are either selected by means of the keywords
TR for translation (TRANS, internal 0)
RT for rotation (ROT, internal 1)
SC for scaling and (SCALE, internal 3)
MI for mirroring (MIRROR, internal 4)
or they are specified directly as an integral value 0, 1, 3, 4.
Example: Access to the rotation around the X axis of the current settable frame.
R10=$P_UIFR[$AC_IFRNUM, X, RT] can also be programmed as:
R10=$P_UIFR[$AC_IFRNUM, X, 1]
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Address frame components only with the keywords provided; program the scale factor
between the limits of 0.000 01 to 999.999 99.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 GUD variable not existing
%1 = Channel number
%2 = Block number, label
The required GUD variable was not found for a MEACALC procedure during read or write
access.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.