11.02
No. 27
Explanation
Not allowed if
Remedy
No. 28
Explanation
Not allowed if
Remedy
No. 29
Explanation
Not allowed if
Remedy
No. 30
Explanation
Not allowed if
Remedy
No. 31
Explanation
Not allowed if
Remedy
No. 32
Explanation
Not allowed if
Remedy
No. 33
Explanation
Not allowed if
Remedy
No. 34
Explanation
Not allowed if
Remedy
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Start continuation of the selected processing -JOG, reference point or digitizing. (VDI sig-
nal: NC Start)
1. Jog motion active
2. An alarm reaction is pending which prevents a start or forces braking.
-
> Execute condition for clearing alarm
Start processing in the digitizing submode. (VDI signal: NC Start)
1. Jog motion active
2. An alarm reaction is pending which prevents a start or forces braking.
3. Reference point approach has not been performed yet.
-
> Execute condition for clearing alarm
> Reference point approach
Stop all axes. (VDI signal: Stop All or via Reset key)
-
-
Perform a program stop. (NC block: M0)
-
-
Stop the JOG motion. (VDI signal: NC Stop)
-
-
Stop digitizing processing. (VDI signal: NC Stop)
-
-
Start the selected processing. (VDI signal: NC Start)
1. Process change active (operating mode change, activate/deactivate digitizing/over-
store)
2. An alarm reaction is pending which prevents a start or forces braking.
3. A process is running (NC program, block search, loading machine data)
-
> Execute condition for clearing alarm
-
Stop the active processing. (VDI signal: NC Stop)
-
-