Siemens SINUMERIK 840D Series Diagnostics Manual page 302

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
21616
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
21617
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
21618
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
21619
Parameters:
1-302
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
-
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 overlaid motion active at transformation switchover
%1 = Channel number
%2 = Block number, label
The overlaid motion in the BCS changes its significance because of the transformation
change and can therefore lead to undesired axis movements.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Stop on alarm.
Take out the overlaid movement.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 transformation does not allow to traverse the pole
%1 = Channel number
%2 = Block number, label
The preset curve passes through the pole or a forbidden area of the transformation.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Stop on alarm.
- NC Start disable in this channel.
Modify part program (if alarm has occurred in AUTO mode).
To escape from the alarm position, transformation must be deselected (it is not enough to
try a RESET if the transformer remains active when RESET is applied).
Clear alarm with the RESET key. Restart part program
Channel %1 as from block %2 transformation active: overlaid motion too great
%1 = Channel number
%2 = Block number, label
The share of overlaid motion on the transformation-related axes is so high that the path
movement planned by the preparation no longer sufficiently corresponds to the actual
ratio for the interpolation. Strategy of singularities, monitoring of working range limitation
and dynamic Look Ahead are possibly no longer correct.
- Alarm display.
With overlaid motion it is necessary to keep a sufficiently large path safety distance with
regard to poles and working range limitations.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 transformation active: motion not possible
%1 = Channel number
%2 = Block number, label
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents