Siemens SINUMERIK 840D Series Diagnostics Manual page 353

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
27024
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
27030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Stop of the axis with STOP B. Start of the switchover timer after STOP A.
- Mode group not ready.
- Channel not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Eliminate causes of alarm "Safe velocity exceeded" or "Safe end position exceeded" (see
description of these alarms).
Switch control OFF - ON.
Axis %1 stop A triggered
%1 = Axis number
This alarm comes with the alarm 27011 "Safe velocity exceeded" (when configured as
such in $MA_SAFE_VELO_STOP_MODE) or follows from STOP B or an unsuccessful
test stop. It indicates that a "Cancel pulse" has been triggered.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Stop of the axis with STOP A. Pulse delete (via SGA).
- Mode group not ready.
- Channel not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Eliminate causes of "Safe velocity exceeded" or for the previous STOP B (see description
of these alarms).
Switch control OFF - ON.
Axis %1 function not supported on this 611D module
%1 = Axis number
SINUMERIK Safety Integrated can be used only with the 611D Performance control mod-
ules with 2 measuring circuits per drive and cutoff relay. An attempt has been made to
activate a safety function although no such module is plugged in.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department. Replace module or switch off
safety functions in MD $MA_SAFE_FUNCTION_ENABLE.
Switch control OFF - ON.
1 Alarms
1-353

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents