1 Alarms
Remedy:
Program Continuation:
14012
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14013
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14014
Parameters:
1-158
The alarm may have different causes:
• Typing error of the identifier stated in parameter 3
• Check subprogram call/SETINT statement or PROC statement. Reload part program
and release for machining or close MMC editor.
• The PI "_N_ASUP__" FB-4, analogous to the SETINT instruction, might want to select
a non-existent program
• Wrong path definition in subprogram call when subprogram is not called up via a search
path but via an absolute path definition. Examples of complete path definitions: /
_N_directoryName_DIR/_N_programName_SPF or /_N_WKS_DIR/
_N_wpdName_WPD/_N_programName_SPF. directoryName: MPF, SPF, CUS, CMA,
CST (defined directories). wpdName: user-specific identifier of workpiece directory
(max. of 24 characters). programName: name of subprogram (max. of 24 characters)
• Parameter 3 can be a macro name. The macro definition file has an inappropriate con-
tent or it is not stored in the directory DEF_DIR or it has not been set active (via POW-
ERON or via MMC operating step or by PI service 'F_COPY').
• Parameter 3 can be a GUD variable. There is no GUD definition file defining the vari-
able or it is not stored in the directory DEF_DIR or it has not been set active (via the
INITIAL_INI procedure or via MMC operating step or by PI service 'F_COPY').
• The part program could also be started from the CPU (ASUP).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 maximum subroutine level exceeded
%1 = Channel number
%2 = Block number, label
The maximum nesting depth of 8 program levels has been exceeded.
Subroutines can be called from the main program, and these in turn may have a nesting
depth of 7.
In interrupt routines the maximum number of levels is 4!
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Modify the machining program so that the nesting depth is reduced, e.g. using the editor
copy a subroutine of the next nesting level into the calling program and remove the call for
this subroutine. This reduces the nesting depth by one program level.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 number of subroutine passes invalid
%1 = Channel number
%2 = Block number, label
In a subroutine call the programmed number of passes P is zero or negative.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Program number of passes between 1 and 9 999.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 selected program %3 not available or will be edited
%1 = Channel number
%2 = Block number, label
%3 = Program name