Remedy:
Program Continuation:
12360
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12370
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12380
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. In predefined
procedures and functions either remove the following parameters or transfer any preced-
ing axis parameters. In user-defined procedures and functions, parameter transfer must
be programmed in accordance with the instructions given in the machine manufacturer's
programming guide.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 dimension of parameter %3 incorrect
%1 = Channel number
%2 = Block number, label
%3 = Source string
The following possibilities of error must be checked:
• The current parameter is an array, but the formal parameter is a variable
• The current parameter is a variable, but the formal parameter is an array
• The current and formal parameters are arrays, but not with the dimensions to be
defined.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Correct the NC
part program in accordance with the cause of error as listed above.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 range of values %3 not permissible
%1 = Channel number
%2 = Block number, label
%3 = Source string
A variable has been initialized with a value range outside an initialization block. The defi-
nition of program-global variables is allowed only in special initialization blocks. These
variables can be initialized with a value range.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Remove the value range specification (begins with the keyword OF) or define the variable
as a global variable in the initialization block and initialize it with a value range.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 maximum memory capacity reached
%1 = Channel number
%2 = Block number, label
The data definitions in this block cannot be processed because the maximum available
memory for creating the data has been filled, or because the data block cannot accommo-
date any further data.
The alarm can also occur if several subroutine calls are executed in sequence and no