Siemens SINUMERIK 840D Series Diagnostics Manual page 296

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
20146
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20147
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20148
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-296
Correct error in expression.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 motion synchronous action: nesting depth exceeded
%1 = Channel number
%2 = Block number
For calculating arithmetic expressions in motion synchronous blocks, an operand stack
with a fixed set size is used. With very complex expressions, this stack can overflow.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Correct error in expression.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 motion synchronous action: command not executable
%1 = Channel number
%2 = Block number
One of the commands for the synchronous action block cannot be executed, e.g. it is not
possible to perform a Reset to the synchronous action.
Measurement level 2
• Embargo version does not allow measurement from a synchronized action
• MEASA was programmed in a synchronized action
• Measurement is already active
• Programming error (see alarm 21701)
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Change synchronous action.
Measurement level 2
Execute the measurement task from an NC program first, in order to improve the error
diagnostics. Only include it in the synchronized action when the first error-free run has
been performed.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 motion synchronous action: internal error %3
%1 = Channel number
%2 = Block number
%3 = Error code
An internal error has occurred during processing of a synchronous action. The error code
is for diagnostics purposes. Please make a note and contact the manufacturer.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Change synchronous action.
Clear alarm with the RESET key. Restart part program
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents