1 Alarms
Remedy:
Program Continuation:
14197
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14198
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14199
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14200
Parameters:
1-182
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 D number and H number programmed simultaneously
%1 = Channel number
%2 = Block number, label
A D word and H word have been programmed simultaneously.
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal change of tool direction with tool offset
%1 = Channel number
%2 = Block number, label
If an offset is active in the tool direction, block change is not possible if this would change
the assignment of the offset axes to the channel axes (plane change, tool change, cutter
<=> turning tool, geometry axis replacement).
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
• Modify part program.
• Reduce the offset in tool direction to zero.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 illegal plane change for tool with diameter component
%1 = Channel number
%2 = Block number, label
If a tool has a wear or length component which is evaluated as a diameter for the facing
axis (bit 0 and/or bit 1 in MD $MC_TOOL_PARAMETER_DEF_MASK is set) and bit 2 of
this MD is also set, this tool may only be used in the plane active on tool selection. A
plane change results in an alarm.
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
- NC Stop on alarm at block end.
• Modify part program.
• Reset bit 2 in MD $MC_TOOL_PARAMETER_DEF_MASK.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 negative polar radius
%1 = Channel number
%2 = Block number, label
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition