11.02
Remedy:
Program Continuation:
17500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
17501
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Modify NC program: Assign the value of the machine data or of the system variable to a
program-local variable and transfer this as parameter.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 axis %3 is not an indexing axis
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
An indexing axis position has been programmed for an axis with the keywords CIC, CAC
or CDC that has not been defined as indexing axis in the machine data.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Remove programming
instruction for indexing axis positions (CIC, CAC, CDC) from the NC part program or
declare the relevant axis to be an indexing axis.
Indexing axis declaration:
Modify MD 30500: INDEX_AX_ASSIGN_POS_TAB
(indexing axis assignment)
The axis will become an indexing axis when an assignment to an indexing position table
was made in the stated MD. Two tables are possible (input value 1 or 2).
Modify MD 10900: INDEX_AX_LENGTH_POS_TAB_1
Modify MD 10920: INDEX_AX_LENGTH_POS_TAB_2
(Number of positions for 1st/2nd indexing axis)
Standard value: 0 Maximum value: 60
Modify MD 10910: INDEX_AX_POS_TAB_1 [n]
Modify MD 10930: INDEX_AX_POS_TAB_2 [n]
(Positions of the 1st indexing axis) The absolute axis positions are entered. (The list
length is defined via MD 10900).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 indexing axis %3 with Hirth tool system is active
%1 = Channel number
%2 = Block number, label
%3 = Axis name
The 'Hirth tooth system' function is activated for the indexing axis. This axis can therefore
approach only indexing positions, another travel movement of the axis is not possible.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
Correct part program.
Correct FC16 or FC18 call.
Deselect machine data $MA_HIRTH_IS_ACTIVE.
Clear alarm with the RESET key. Restart part program