11.02
Reactions:
Remedy:
Program Continuation:
310709
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
310710
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Match the number of encoder marks of the motor measuring system in drive MD 5005:
ENC_RESOL_MOTOR (number of encoder marks of the motor measuring system) to the
encoder in use. (Default setting for motor measuring system: (Default setting for motor
measuring system: 2048 incr./rev.).
Switch control OFF - ON.
Axis %1 drive %2 error in piston diameter or piston rod diameter
%1 = NC axis number
%2 = Drive number
The piston diameter in drive MD 5131: CYLINDER_PISTON_DIAMETER is less than or
equal to zero or the piston rod diameter in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER is greater than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER or the piston rod diameter in drive MD 5133:
CYLINDER_PISTON_ROD_B_DIAMETER is greater than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER.
- NC not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Enter a valid piston diameter in drive MD 5131: CYLINDER_PISTON_DIAMETER (0 < D
<= 500mm). or Enter a piston rod diameter in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER which is less than the piston diameter in drive
MD 5131: CYLINDER_PISTON_DIAMETER or Enter a piston rod diameter in drive MD
5133: CYLINDER_PISTON_ROD_B_DIAMETER which is less than the piston diameter
in drive MD 5131: CYLINDER_PISTON_DIAMETER.
Switch control OFF - ON.
Axis %1 drive %2 distance-coded scale incorrectly parameterized
%1 = NC axis number
%2 = Drive number
If a distance-coded scale is selected (MD 5011 bit 7=1) a length measuring system must
also be configured (MD 5011 bit 4=1).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Check and, if necessary, correct MD 5011: ACTUAL_VALUE_CONFIG (actual value
sensing configuration).
Switch control OFF - ON.