Siemens SINUMERIK 840D Series Diagnostics Manual page 29

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
4012
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4013
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
4014
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Invalid identifier used in machine data %1[%2]
%1 = String: MD identifier
%2 = Index: MD array index
The selected identifier is invalid. Valid identifiers are:
• AX1 - AXn: Machine axis identifiers
• N1AX1 - NnAXm: Link axis identifiers (NCU + machine axis), only occurs with 'NCU link'
expansion level!
• C1S1 - CnSm: Container axis identifiers (container + container location). Only occurs
with 'axis container' expansion level!
- Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Use the correct identifier.
Switch control OFF - ON.
Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3
%1 = String: MD identifier
%2 = Index: MD array index
%3 = MD value of master NCU
The link module configuration detected on the local NCU is different from the master NCU
of the NCU cluster. The link module configuration defines the system clock time, the com-
munication baudrate and the maximum number of message transfer retries.
The following machine data are used for this purpose:
• SYSCLOCK_SAMPL_TIME_RATIO,
• IPO_SYSCLOCK_TIME_RATIO,
• LINK_RETRY_CTR,
• LINK_BAUDRATE_SWITCH,
• SYSCLOCK_CYCLE_TIME
The values of these machine data must be the same on all NCUs.
- Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
The machine data required for the link module configuration must be the same on all
NCUs in the cluster.
Switch control OFF - ON.
Axis %1 defined several times in %2
%1 = String: MD identifier
%2 = String: Check and, if necessary, correct the following machine data with reference to
the data sheet:
An axis was assigned several times.
The axis can be a:
• Machine axis
• Link axis
• Axis in a container location