1 Alarms
10860
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10861
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10862
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10870
Parameters:
1-112
Channel %1 block %2 feedrate not programmed
%1 = Channel number
%2 = Block number, label
In the displayed block, an interpolation type other than G00 (rapid traverse) is active. The
F value has not been programmed.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- Correction block is reorganized.
Program feedrate in accordance with the interpolation type.
• G93: The feedrate is specified as a time-reciprocal value under address F in [1/min].
• G94 and G97: The feedrate is programmed under address F in [mm/min] or [m/min].
• G95: The feedrate is programmed as revolutional feedrate under address F in [mm/rev-
olution].
• G96: The feedrate is programmed as cutting rate under address S in [m/min]. It is
derived from the current spindle speed.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %3 velocity of positioning axis %2 is zero
%1 = Channel number
%2 = Axis
%3 = Block number, label
No axis velocity has been programmed and the positioning velocity set in the machine
data is zero.
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Enter a different velocity in
machine data 32060 MA_POS_AX_VELO.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 master spindle also used as path axis
%1 = Channel number
%2 = Block number, label
A contour has been programmed that also includes the master spindle as contouring axis.
However, the velocity of the contour is derived from the rotational speed of the master
spindle (e.g. G95).
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- Correction block is reorganized.
Modify the program so that no reference is possible to the program itself.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 facing axis not defined
%1 = Channel number
%2 = Block number, label
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02