Siemens SINUMERIK 840D Series Diagnostics Manual page 562

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
311710
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
311711
Parameters:
Definitions:
Reactions:
Remedy:
1-562
- NC not ready.
- Channel not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
The knee area and the saturation area overlap if:
• Positive quadrant: (MD 5465 + MD 5466) > MD 5486
• Negative quadrant: (MD 5468 + MD 5466) > MD 5488
Enter a valid combination in the above drive MD.
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 resolution SSI motor measuring system invalid
%1 = NC axis number
%2 = Drive number
The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_5022 $MD_ENC_ABS_RESOL_MOTOR must not be 0.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Set MD_5022 $MD_ENC_ABS_RESOL_MOTOR to correct value:
• Rotary encoder: Singleturn resolution (increments per revolution).
• Linear encoder: Resolution of an increment (in nanometers).
Switch control OFF - ON.
Axis %1 drive %2 transmission length SSI motor measuring system invalid
%1 = NC axis number
%2 = Drive number
The configuration of the motor measuring system for an SSI encoder is incorrect:
MD_5028 $MD_NO_TRANSMISSION_BITS (SSI frame length) is smaller than the num-
ber of all parameterized bits in MD_5021 $MD_ENC_ABS_TURNS_MOTOR (multiturn),
MD_5022 $MD_ENC_ABS_RESOL_MOTOR (singleturn) and MD_5027 $MD_ENC_
CONFIG bit 14 (alarm bit) and MD_5027 $MD_ENC_CONFIG bit 12 (parity bit).
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Set parameters correctly for all associated machine data:
• MD_5028 $MD_NO_TRANSMISSION_BITS (SSI frame length): number of bits in an
SSI protocol, including all bits, such as alarm bit/parity bit
• MD_5021 $MD_ENC_ABS_TURNS_MOTOR (multiturn): no. of resolvable revolutions
• MD_5022 $MD_ENC_ABS_RESOL_MOTOR (singleturn): number of increments per
revolution
• MD_5027.Bit 12 $MD_ENC_CONFIG.Bit 12: parity bit
• MD_5027.Bit 14 $MD_ENC_CONFIG.Bit 14: alarm bit
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents