Siemens SINUMERIK 840D Series Diagnostics Manual page 208

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
15025
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15030
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15100
Parameters:
Definitions:
1-208
Program CHANDATA instruction in accordance with the actual configuration.
Clear alarm with the RESET key. Restart part program
CHANDATA(%2): channel is not active. Channel data will be ignored.
%1 = Channel number
%2 = CHANDATA parameter
With a CHANDATA instruction, the data input for a channel is selected that has not been
activated.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
This is an informational alarm referring to the fact that the file loaded into the NCK con-
tains data of an inactive channel. The number of the inactive channel is specified. Subse-
quently, the data of this channel are not available in the NCK.
The alarm may have two causes:
(1.) The channel is supposed to be activated by a following NCK RESET/POWER ON, i.e.
the file must subsequently be reloaded.If the alarm occurs again, the reason is: (2) the
specified channel is actually not supposed to be activated, however, the file contains the
relevant data.
For the second reason, please check whether the system has correctly not activated the
channel mentioned.
If the channel has been activated, operation may be continued after another NCK RESET/
POWER ON without further measures, i.e. reloading the file is not required. If the channel
has not been activated, make sure that the channel inactivated by mistake is re-activated.
If the settings of the channel activation are part of the file to be loaded (e.g. archive file),
the file must either be modified with the relevant program or the file has to be created
once more in the same system with the correct channel number.
Similar alarms: 15020, 15021.
Switch control OFF - ON.
Channel %1 block %2 different measurement system settings
%1 = Channel number
%2 = Block number, label
The INCH or METRIC instruction describes the system of measurement in which the data
blocks have been read from the control. In order to prevent the incorrect interpretation of
data intended for a particular system of measurement, a data block is only accepted if the
above instruction matches the active system of measurement.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Change the system of measurement or load a data block which matches the system of
measurement.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 REORG abort caused by log file overflow
%1 = Channel number
%2 = Block number, label
In order to synchronize the preprocessing run and the main run with REORG, the control
accesses modification data which are maintained in a logfile. The alarm indicates that no
more capacity is available in the logfile for the specified block in the channel.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents