Siemens SINUMERIK 840D Series Diagnostics Manual page 118

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Remedy:
Program Continuation:
10934
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10940
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
10941
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-118
Increase the size of the subroutine with the stock removal contour to include at least 3 NC
blocks with movements in both axes of the current machining plane.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 array for contour segmentation is set too small
%1 = Channel number
%2 = Block number, label
During contour segmentation (activated with the keyword CONTPRON), the field for the
contour table has been detected as too small. For every permissible contour element (cir-
cle or straight line) there must be a row in the contour table.
- Local alarm reaction.
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
Base the definition of the field variables of the contour table on the contour elements to be
expected. The contour segmentation function divides up some NC blocks into as many as
3 machining cuts. Example: N100 DEF TABNAME_1 [30, 11] Field variables for the con-
tour table provide for 30 machining cuts. The number of columns (11) is a fixed quantity.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: delete/overwrite not possible
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
The curve table can only be deleted if it is not active in a link.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
It is necessary to deactivate all links that are being used by the curve table to be deleted.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 curve table %3: NC memory full
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
The free dynamic disk space is exceeded during definition of the curve table.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Please inform the authorized personnel/service department. Delete curve tables that are
no longer required, or reconfigure the disk space for the curve tables. The curve table def-
inition process now has to be repeated; see machine data:
MD MN_MM_NUM_CURVE_TABS, MD MN_MM_NUM_CURVE_SEGMENTS, MD
MN_MM_NUM_CURVE_POLYNOMS.
Clear alarm with the RESET key. Restart part program
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents