1 Alarms
Reactions:
Remedy:
Program Continuation:
14401
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14402
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14403
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14404
Parameters:
Definitions:
1-186
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Perform tool radius compensation in the NC part program with G40 (in a block with G00 or
G01) before performing a transformation change.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 transformation not available
%1 = Channel number
%2 = Block number, label
The required transformation is not available.
- Alarm display.
- Interface signals are set.
- Interpreter stop
- NC Start disable in this channel.
Please inform the authorized personnel/service department.
• Modify part program; program defined transformations only.
• Check MD 24100 TRAFO_TYPE_n (assigns the transformation to part program instruc-
tions).
Clear alarm with the RESET key. Restart part program
Channel %1 block %2 spline active at transformation change
%1 = Channel number
%2 = Block number, label
A change of transformation is not allowed in a spline curve section. A series of spline
blocks must be concluded.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 preprocessing and main run might not be synchronized
%1 = Channel number
%2 = Block number, label
Positioning axis runs cannot be accurately calculated beforehand. Consequently, the
position in the MCS is not known exactly. It might therefore be possible that a change in
the multiple significance of the transformation has been performed in the main run
although no provision was made for this in the preprocessing run.
- Alarm display.
Modify part program. Synchronize preprocessing run and main run.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 illegal parameterization of transformation
%1 = Channel number
%2 = Block number, label
Error has occurred when selecting transformation.