Strip Chart Program
6.7 VERIFYING THE SETUP
The "W=t-1f' command is used to verify that the current setup correctly matches the hardware
configuration of the HP 3421A Data Acquisition/Control Unit connected to the HP-71. This command
should be used when an existing strip chart setup has been retrieved from storage, prior to running the
strip chart session.
To use the "et 1+ command, press
from the file menu:
Get Hew Sauve Yer Main™
The file menu.
Press
to select the "=r" 1f'4 command.
Trace
1
...
As each trace is examined, the program displays a status
message.
If an error is encountered, it will be displayed,
and the program will proceed to the next trace.
Edit File Eun Cait?
When all of the traces have been examined, the program
returns to the main menu.