IR compensation for a scalar controlled drive

IR compensation is active only when the motor
control mode is scalar (see section
control
on page 146). When IR compensation is
activated, the drive gives an extra voltage boost
to the motor at low speeds. IR compensation is
useful in applications that require high break-
away torque. In vector control, no IR
compensation is possible/needed.
Settings
Parameter
2603 IR COMP VOLT
Programmable protection functions
AI<Min
AI<Min function defines the drive operation if an analog input signal falls below the
set minimum limit.
Settings
Parameters
3001 AI<MIN
LIMIT
Panel loss
Panel loss function defines the operation of the drive if the control panel selected as
the control location for the drive stops communicating.
Settings
Parameter
3002 PANEL COMM ERR
External fault
External faults (1 and 2) can be supervised by defining one digital input as a source
for an external fault indication signal.
Settings
Parameters
3003 EXTERNAL FAULT 1
Stall protection
The drive protects the motor in a stall situation. It is possible to adjust the supervision
limits (frequency, time) and choose how the drive reacts to the motor stall condition
(alarm indication / fault indication & drive stop / no reaction).
Scalar
FUNCTION,
3021 AI1 FAULT LIMIT
and
3004 EXTERNAL FAULT 2
Program features 147
Motor voltage
IR compensation
No compensation
and
3022 AI2 FAULT
f (Hz)