State shifts

From any state
MODULATION
BRAKE
RELEASE RFG
RFG INPUT
TO ZERO
CLOSE
BRAKE
State (Symbol
- NN: State name
- X/Y/Z: State outputs/operations
X = 1
Open the brake. The relay output set to brake on/off control energizes.
Y = 1
Forced start. The function keeps the internal Start on until the brake is closed in
spite of the status of the external Start signal.
Z = 1
Ramp in zero. Forces the used speed reference (internal) to zero along a ramp.
State change conditions (Symbol
1)
Brake control active 0 -> 1 OR Inverter is modulating = 0
2)
Motor magnetised = 1 AND Drive running = 1
3)
Brake is open AND Brake open delay passed AND Start = 1
4)
Start = 0
5)
Start = 0
6)
Start = 1
7)
Actual motor speed < Brake close speed AND Start = 0
8)
Start = 1
9)
Brake is closed AND Brake close delay passed = 1 AND Start = 0
(rising edge)
1)
NO
0/0/1
2)
OPEN
1/1/0
3)
1/1/0
INPUT
4)
1/1/1
7)
0/1/1
8)
9)
X/Y/Z
NN
)
)
A
5)
6)
A
RFG = Ramp function
generator in the speed control
loop (reference handling).