312 Actual signals and parameters
All parameters
No.
Name/Value
9912 MOTOR NOM
TORQUE
0...3000.0 N·m Read-only
9913 MOTOR POLE
PAIRS
-
9914 PHASE
INVERSION
NO
YES
9915 MOTOR COS
PHI
0 ... 0.97
Description
Calculated motor nominal torque in N·m (calculation is
based on parameter
9909 MOTOR NOM POWER
MOTOR NOM SPEED
Calculated motor pole pair number (calculation is based on
parameter
9907 MOTOR NOM FREQ
NOM SPEED
values).
Read-only
Inverts two phases in the motor cable. This changes the
direction of the motor rotation without having to exchange
the positions of two motor cable phase conductors at the
drive output terminals or at the motor connection box.
Phases not inverted
Phases inverted
When set to 0, an estimated cos phi value is used.
Active range of the parameter is 0.5 ... 0.97 and should be
used when high efficiency motors (IE3 or IE4) are used.
values).
and
9908 MOTOR
Def/FbEq
0
and
9908
1 =
0.1 N·m
0
1 = 1
NO
0
1
0
1 = 0.01