Timed Functions - ABB ACS355 series User Manual

Hide thumbs Also See for ACS355 series:
Table of Contents

Advertisement

All parameters
No.
Name/Value
DI3
DI4
DI5
3503 ALARM LIMIT
x...x
3504 FAULT LIMIT
x...x
3505 AO
EXCITATION
DISABLE
ENABLE
36 TIMED
FUNCTIONS
3601 TIMERS
ENABLE
NOT SEL
DI1
DI2
DI3
DI4
DI5
ACTIVE
DI1(INV)
DI2(INV)
DI3(INV)
Description
Digital input DI3. Used when parameter
TYPE
value is set to THERM(0)/THERM(1).
Digital input DI4. Used when parameter
TYPE
value is set to THERM(0)/THERM(1).
Digital input DI5. Used when parameter
TYPE
value is set to THERM(0)/THERM(1).
Defines the alarm limit for motor temperature measurement.
Alarm
MOTOR TEMP
limit is exceeded. When parameter
value is set to THERM(0)/THERM(1): 1 = alarm.
Alarm limit
Defines the fault trip limit for motor temperature
measurement. The drive trips on fault
(0009) when the limit is exceeded. When parameter
SENSOR TYPE
value is set to THERM(0)/THERM(1): 1 =
fault.
Fault limit
Enables current feed from analog output AO. Parameter
setting overrides parameter group
settings.
With PTC the output current is 1.6 mA.
With Pt 100 the output current is 9.1 mA.
Disabled
Enabled
Time periods 1 to 4 and booster signal. See section
time clock and timed functions
Selects the source for the timed function enable signal.
Timed function is not selected.
Digital input DI. Timed function enable on the rising edge of
DI1.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
Timed function is always enabled.
Inverted digital input DI1. Timed function enable on the
falling edge of DI1.
See selection DI1(INV).
See selection DI1(INV).
Actual signals and parameters 269
3501 SENSOR
3501 SENSOR
3501 SENSOR
(2010) indication is given when the
3501 SENSOR TYPE
MOT OVERTEMP
15 ANALOG OUTPUTS
on page 165.
Def/FbEq
5
6
7
0
-
0
3501
-
DISABLE
0
1
Real-
NOT SEL
0
1
2
3
4
5
7
-1
-2
-3