112 Application macros

Alternate macro

This macro provides an I/O configuration adapted to a sequence of DI control signals
used when alternating the rotation direction of the motor. To enable the macro, set the
value of parameter
For the parameter default values, see section
page 180. If you use other than the default connections presented below, see section
I/O terminals
on page 53.
Default I/O connections
1...10 kohm
max. 500 ohm
1)
See parameter group
DI3
DI4 Operation (parameter)
0
0
Set speed through AI1
1
0
Speed 1 (1202)
0
1
Speed 2 (1203)
1
1
Speed 3 (1204)
9902 APPLIC MACRO
X1A
1
SCR
2
AI1
3
GND
4
+10V
5
AI2
6
GND
7
AO
8
GND
3)
9
+24V
10 GND
11 DCOM
12 DI1
13 DI2
14 DI3
15 DI4
16 DI5
X1B
17 ROCOM
18 RONC
19 RONO
20 DOSRC
21 DOOUT
22 DOGND
12 CONSTANT
SPEEDS:
to 3 (ALTERNATE).
Default values with different macros
Signal cable shield (screen)
Motor speed reference: 0...10 V
Analog input circuit common
Reference voltage: +10 V DC, max. 10 mA
Not in use by default. 0...10 V
Analog input circuit common
Motor speed value: 0...20 mA
Analog output circuit common
Auxiliary voltage output: +24 V DC, max. 200 mA
Auxiliary voltage output common
Digital input common
Start forward: If DI1 = DI2, the drive stops.
Start reverse
Constant speed selection
Constant speed selection
Acceleration and deceleration selection
Relay output 1
No fault [Fault (-1)]
Digital output, max. 100 mA
No fault [Fault (-1)]
2)
0 = ramp times according to parameters
2203.
1 = ramp times according to parameters
2206.
3)
360 degree grounding under a clamp.
Tightening torque: 0.4 N·m / 3.5 lbf·in.
Safe torque off connections (X1C:STO; not shown in
the diagram) are jumpered by default.