ABB ACS355 Supplement Manual
ABB ACS355 Supplement Manual

ABB ACS355 Supplement Manual

High speed program (+n826)
Hide thumbs Also See for ACS355:

Advertisement

Quick Links

ABB machinery drives
Supplement
ACS355 high speed program (+N826)

Advertisement

Table of Contents
loading

Summary of Contents for ABB ACS355

  • Page 1 ABB machinery drives Supplement ACS355 high speed program (+N826)
  • Page 2 List of related manuals Drive manuals and guides Code (English) ACS355 user’s manual 3AUA0000066143 ACS355 drives with IP66/67 / UL Type 4x enclosure 3AUA0000066066 supplement ACS355 quick installation guide 3AUA0000092940 ACS355 common DC application guide 3AUA0000070130 ACS355 enhanced sequence program (+N830)
  • Page 3 Supplement ACS355 high speed program (+N826) Table of contents 3AXD50000017574 Rev A  2014 ABB Oy. All Rights Reserved. EFFECTIVE: 2014-07-09...
  • Page 5: Table Of Contents

    Providing feedback on ABB Drives manuals ........
  • Page 7: Introduction To The Supplement

    Please study the complete safety instructions carefully. Scope This document is supplement of ACS355 user’s manual (3AUA0000066143 [English]). This supplement covers all differences between high speed program and ACS355 standard firmware. Only the high speed program contents are given in each chapter of this supplement.
  • Page 8: Applicability

    • Appendixes Applicability The manual is applicable to the ACS355 high speed program firmware version 6303 or later. See parameter 3301 FIRMWARE. Option code +N826 in the drive type code shows that the drive has the high speed program installed.
  • Page 9: Contents Of This Supplement

    • Further information (inside of the back cover) tells how to make product and service inquiries, get information on product training, provide feedback on ABB Drives manuals and how to find documents on the Internet. Related documents List of related manuals on page (inside of the front cover).
  • Page 10 10 Introduction to the supplement...
  • Page 11: Program Features

    Program features What this chapter contains The chapter describes ACS355 high speed program features. There are also lists of related user settings in each section. Other standard program features please refer to chapter Program features in ACS355 user’s manual (3AUA0000066143 [English]).
  • Page 12: Fault Reaction For Em Stop

    12 Program features Note: These derating rules do not consider R0 frame.Please check the user’s manual for derating the R0 frame size. Fault reaction for EM STOP Emergency ramp stop in case of non critical faults and 500ms delayed fault for under voltage controller.
  • Page 13: Fault Reaction For Power Loss

    Program features 13 Fault reaction for Power loss When 20.06 UNDERVOLT CTRL = ENABLE(TIME) and 30.29 = ENABLE (fault ramp stop enabled) then drive faults after being in under-voltage control for 500ms. Fault will also trigger an emergency ramp stop. Related parameters are listed in the table below: ...
  • Page 14: Fast User Set Change

    14 Program features Fast user set change Totally 6 user sets and possibility change quickly between them. User can switch from different ramp and controller values for different tools in case machine has several tools. Pararameter 0186 ACTIVE MACRO – shows which user set was last loaded, updated after start inhibits are removed.
  • Page 15: Actual Signals And Parameters

    10 (which is equal to the fieldbus equivalent FbEq). FbEq Fieldbus equivalent: The scaling between the value and the integer used in serial communication. Note: More information about drive parameters please refer to the section Actual signal and parameters in ACS355 User’s manual (3AUA0000066143 [English]).
  • Page 16: Actual Signals

    16 Actual signals and parameters Actual signals Actual signals Name/Value Description FbEq 01 OPERATING Basic signals for monitoring the drive (read-only) DATA 0186 ACTIVE Shows which user macro is loaded. 1 = 1 MACRO...
  • Page 17: Parameters

    Actual signals and parameters 17 Parameters All parameters Name/Value Description Def/FbEq 11 REFERENCE Panel reference type, external control location selection and SELECT external reference sources and limits 1104 REF1 MIN Defines the minimum value for external reference REF1. 0.0 Hz / Corresponds to the minimum setting of the used source 1 rpm signal.
  • Page 18 18 Actual signals and parameters All parameters Name/Value Description Def/FbEq 0.0…1400.0 Hz Speed in rpm. Output frequency in Hz if parameter 9904 1 = 0.1 Hz / 0…32000 rpm MOTOR CTRL MODE setting is SCALAR: FREQ. / 1 rpm 1205 CONST Defines constant speed (or drive output frequency) 4.
  • Page 19 Actual signals and parameters 19 All parameters Name/Value Description Def/FbEq NOT SEL User parameter set change is not possible through a digital input. Parameter sets can be changed only from the control panel. User parameter set control through digital input DI1. Falling edge of digital input DI1: User parameter set 1 is loaded into use.
  • Page 20 20 Actual signals and parameters All parameters Name/Value Description Def/FbEq DI1,2(INV) User parameter set selection through inverted digital inputs DI1 and DI2. 1 = DI inactive, 0 =DI active. DI2 User parameter set User parameter set 1 User parameter set 2 User parameter set 3 User parameter set 4 DI2,3(INV)
  • Page 21 Actual signals and parameters 21 All parameters Name/Value Description Def/FbEq USER S2 User set2 will be saved. SAVE USER S3 User set3 will be saved. SAVE USER S4 User set4 will be saved. SAVE USER S5 User set5 will be saved. SAVE USER S6 User set6 will be saved.
  • Page 22 22 Actual signals and parameters All parameters Name/Value Description Def/FbEq 2007 MINIMUM Defines the minimum limit for the drive output frequency. 0.0 Hz FREQ A positive (or zero) minimum frequency value defines two ranges, one positive and one negative. A negative minimum frequency value defines one speed range.
  • Page 23 Actual signals and parameters 23 All parameters Name/Value Description Def/FbEq SMOOTH Smooth start ramp time will be effect in ramp time according START to settings of parameter 2621...2624. DI1(INV) Inverted digital input DI1. 0 = ramp pair 2, 1 = ramp pair 1. DI2(INV) See selection DI1(INV).
  • Page 24 24 Actual signals and parameters All parameters Name/Value Description Def/FbEq 0.0…1400.0 Hz Frequency 1 = 0.1 Hz 2615 USER Defines the third frequency point of the custom U/f curve. 25.0 Hz DEFINED F3 0.0…1400.0 Hz Frequency 1 = 0.1 Hz 2617 USER Defines the fourth frequency point of the custom U/f curve.
  • Page 25 Actual signals and parameters 25 All parameters Name/Value Description Def/FbEq 99 START-UP DATA Language selection. Definition of motor set-up data. 9902 APPLIC Selects the application macro. MACRO STANDA Standard macro for constant speed applications STANDARD 3-WIRE 3-wire macro for constant speed applications ALTERNATE Alternate macro for start forward and start reverse applications...
  • Page 26 26 Actual signals and parameters All parameters Name/Value Description Def/FbEq USER S2 Save User 2 macro. Stores the current parameter settings SAVE and the motor model. USER S3 User 3 macro loaded into use. Before loading, check that LOAD the saved parameter settings and the motor model are suitable for the application.
  • Page 27: Further Information

    Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/searchchannels.
  • Page 28 Contact us www.abb.com/drives www.abb.com/drivespartners 3AXD50000017574 Rev A (EN) 2014-07-09...

Table of Contents