All parameters
No.
Name/Value
FILTERED DI5 Filtered digital input DI5 pulses. When a pulse is detected,
1907 COUNTER
RESET
DI1(INV)
DI2(INV)
DI3(INV)
DI4(INV)
DI5(INV)
NOT SEL
DI1
DI2
DI3
DI4
DI5
AT LIMIT
STRT/STP
CMD
S/S CMD(INV) Counter reset at start/stop command (inverted), ie, counter
RESET
Description
the counter value increases by 1.
Note: Due to filtering, the maximum input signal frequency
is 50 Hz.
Selects the source for the counter reset signal.
Counter reset through inverted digital input DI1. 0 = active, 1
= inactive.
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
No reset signal
Counter reset through digital input DI1. 1 = active, 0 =
inactive.
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
Reset at the limit defined by parameter
LIMIT
Counter reset at start/stop command. Source for the
start/stop is selected by parameter
COMMAND.
is reset when start/stop command is deactivated. Start
signal source is selected by parameter
START.
Reset enabled
Actual signals and parameters 219
1905 COUNTER
1911 CNTR S/S
1902 TIMER
Def/FbEq
4
NOT SEL
-1
-2
-3
-4
-5
0
1
2
3
4
5
6
7
8
9