386 Technical data
Maximum
recommended
motor cable length
Operational functionality and motor cable length
The drive is designed to operate with optimum performance with the
following maximum motor cable lengths. The motor cable lengths may
be extended with output chokes as shown in the table.
Frame
size
Standard drive, without external options
R0
R1...R4
With external output chokes
R0
R1...R4
Note: In multimotor systems, the calculated sum of all motor cable
lengths must not exceed the maximum motor cable length given in
the table.
EMC compatibility and motor cable length
To comply with the European EMC Directive (standard
IEC/EN 61800-3), use the following maximum motor cable lengths
for 4 kHz switching frequency.
All frame
sizes
With internal EMC filter
Second environment
1)
(category C3
)
With optional external EMC filter
Second environment
1)
(category C3
)
First environment
1)
(category C2
)
First environment
1)
(category C1
)
1)
See the terms in section
2)
Maximum motor cable length is determined by the drive's
operational factors. Contact your local ABB representative for the
Note 1: The internal EMC filter must be disconnected by removing
the EMC screw (see the figure on page 50) while using the low
leakage current EMC filter (LRFI-XX).
Note 2: Radiated emissions are according to C2 with and without an
external EMC filter.
Note 3: Category C1 with conducted emissions only. Radiated
emissions are not compatible when measured with standard
emission measurement setup and should be checked or measured
on cabinet and machine installations case by case.
Maximum motor cable length
m
30
50
60
100
Maximum motor cable length, 4 kHz
m
30
2)
30 (at least)
2)
30 (at least)
2)
10 (at least)
Definitions
on page 391.
ft
100
165
195
330
ft
100
2)
100 (at least)
2)
100 (at least)
2)
30 (at least)