5. Remove the Suction filter out of the box.
6. Place the new Suction filter into the box and push the tray back in until it stops and
is flush with the press.
7. Place the cover back onto the filter box area. Make sure to first insert the left two
tabs of the cover into the left side of the box area. Then push the entire cover flush
to the press.
8. Insert the Torx driver with the screw attached into the cover and turn clockwise to
tighten.
9. Either log in as the administrator or ask the administrator to perform the following
steps to reset the counter to zero (0), which indicates a new filter has been installed.
a) At the UI, press the Machine Status button.
b) From the screen that displays, select the Tools tab.
c) Select System Settings > Common Service Settings > Maintenance.
d) Use the up/down arrow buttons to access the next Maintenance screens.
e) Select the Technical Key Operator icon. The Technical Key Operator feature
displays.
f) Select the CRU item that corresponds with the newly-replaced component.
g) Select Reset Current Value. The system resets the HFSI to 0.
10. Exit administrator mode by pressing the Log In/Out button on the Control Panel.
When prompted, select Logout.
®
®