Tm54F: Acknowledgement On The Control Unit Is Required; Tm54F: Drive Object Number Assignment Illegal; Tm54F: Test Stop Active; Tm54F: Test Stop Error - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Cause:
The commissioning mode setting was rejected because for at least one drive belonging to the TM54F, the pulses had
not been suppressed.
Fault value (r0949, interpret decimal):
Drive object number of the first drive found without pulse suppression.
Remedy:
Cancel the pulses for the drive specified in the fault value.
235003
<location>TM54F: Acknowledgement on the Control Unit is required
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
A fault on the Terminal Module 54F (TM54) was acknowledged using the safe acknowledgement (P10006).
An additional acknowledgement is also required at the Control Unit.
Remedy:
Acknowledge the fault at the Control Unit.
235011
<location>TM54F: Drive object number assignment illegal
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
A drive object number was assigned twice. Each drive object number can be assigned only once.
Remedy:
Correct the assignment of the drive object numbers.
See also: p10010 (SI drive object assignment)
235012
<location>TM54F: Test stop active
Message value:
-
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
NONE
Cause:
The test stop for the Terminal Module 54F (TM54F) is presently being executed.
F35013 is output when a error occurs during the test stop.
Remedy:
The alarm disappears automatically after successfully ending or canceling (when a fault condition occurs) the test
stop.
235013
<location>TM54F: Test stop error
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM54F_MA, TM54F_SL
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
SINAMICS alarms
847

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents