16678
[Channel %1: ] Block %2 following axis/spindle %3 status %4 impermissible traversing
instruction
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Status
Definitions:
An addtional traversing in the following axis/spindle is not permitted in the current status
of the generic coupling.
Example: CPOF=X G0 X100 is not permitted.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
A motion in the following axis/spindle can be programmed with CPFPOS, CPON or CPOF
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16680
[Channel %1: ] Block %2 following axis/spindle %4 instruction %3 programmed
repeatedly
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = CP instruction
%4 = Axis name, spindle number
Definitions:
The stated instruction has been programmed repeatedly in the block for the same following
axis/spindle of a generic coupling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16681
[Channel %1: ] Block %2 following axis/spindle %3 CPFPOS not permitted (reason %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reason
Definitions:
CPFPOS must not be declared for a following axis/spindle of a generic coupling in the current status. The reasons for
this may be:
- Reason 1: The coupling does not completely switch off, at least one leading axis/spindle remains active in the cou-
pling.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The following remedies are available for the reasons stated below:
- Reason 1: Only declare CPFPOS when switching off the coupling, if it is completely closed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
230
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms