NCK alarms
16933
[Channel %1: ] Interrupt treatment: action %2<ALNX> not allowed in the current state
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
If a temporary standstill has occurred because of a Reorg event across block boundaries, it is possible that a block
without Reorg capability has been loaded. In this situation, it is unfortunately necessary to abort the Reorg event han-
dling! Reorg events are, e.g. abort subprogram, delete distance-to-go and interrupts.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Abort program with the RESET key.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16934
[Channel %1: ] Interrupt treatment: action %2<ALNX> not possible due to stop
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Reorg events are, e.g. abort subprogram, delete distance to go and interrupts, axis exchange, termination of follow-
up mode. Two Reorg events overlap in this situation. The 2nd Reorg event coincides with the 1st block generated by
the previous event. (e.g. an axis exchange is induced twice in rapid succession). Axis exchange leads to Reorg in the
channels in which an axis is removed without preparation. This block must be stopped in the above sequence in order
to prevent the interpolator buffer from overflowing. This can be achieved by pressing the Stop or StopAll key, config-
uring an alarm with INTERPRETERSTOP or by decode single block.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
The program must be aborted with Reset.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16935
[Channel %1: ] Action %2<ALNX> not possible due to search run
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The action is not allowed as block search is currently running via program test. Block search via program test: "PI Ser-
vice _N_FINDBL with mode parameter 5_.
With this block search type, it is not permissible to activate program test or dry run feedrate.
Reaction:
Alarm display.
Remedy:
Activate the action after block search is terminated.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16936
[Channel %1: ] Action %2<ALNX> not possible due to active dry run
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
This action is not allowed as dry run feedrate is currently active.
Example: It is not permissible to activate block search via program test (PI service _N_FINDBL with mode parameter
5) when dry run feedrate is active.
256
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms