Block %2 No Valid Transformation Machine Data Parameterized; Block %2 Modal Macro Call %3 Not Possible; Block %2 Illegal End Of File; Block %2 Illegal End Of Block - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
12730
[Channel %1: ] Block %2 no valid transformation machine data parameterized
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machine data MD24100 $MC_TRAFO_TYPE_1, MD24110 $MC_TRAFO_AXES_IN_1[1], MD24210
$MC_TRAFO_AXES_IN_2[1] are incorrectly set for G07.1, G12.1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Enter valid transformation identifier for TRACYL in MD24100 $MC_TRAFO_TYPE_1 and the rotary axis number in
MD24110 $MC_TRAFO_AXES_IN_1[1] or MD24210 $MC_TRAFO_AXES_IN_2[1].
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12740
[Channel %1: ] Block %2 modal macro call %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
When calling a modal macro no other modal macro, modal cycle or modal subroutine may be active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14000
[Channel %1: ] Block %2 illegal end of file
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm 14000 is output in the following situations:
- Parts program was not terminated with M30, M02 or M17.
- Executing from external: Download was aborted (e.g. because HMI was switched off).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- End parts program with M30, M02 or M17 and start parts program.
- Executing from external: If the download for the selected program was aborted,
the default program _N_MPF0 is automatically selected with RESET
The selection of the user program must be repeated after that.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14001
[Channel %1: ] Block %2 illegal end of block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
After system-internal data manipulation (e.g. when reloading from an external source) a part file can end without hav-